WaterFurnace Envision NXW Reversible Chiller Parts by Model
2 model pages for model numbers starting NXW. Each lists the genuine WaterFurnace parts we’ve confirmed fit that unit.
The Envision NXW is a WaterFurnace reversible water-to-water chiller: it heats or chills water for hydronic systems. The NXW installation manual lists sizes from 096 to 540 MBtu/h (8 to 50 tons). WaterFurnace’s naming-convention sheet lists the Envision2 NXW chiller among the previous names now grouped under its TruClimate 100 water-to-water line.
Pick your model below to see the parts we’ve confirmed fit it.
Pick your model
- NXW240Water-to-water, reversible · 20 tons30 confirmed parts · 1 model number
- NXW360Water-to-water, reversible · 30 tons62 confirmed parts · 3 model numbers
Type the model number from the unit’s nameplate (for example NDV064A111CTL), the first 7 characters, or a series name like “7 Series”.
WaterFurnace 5 Series
- NDH026B2 tons · 43 partsNDH026B101CSL, NDH026B101CSR
- NDH026G2 tons · 39 partsNDH026G101CEL0BA
- NDH038A3 tons · 42 partsNDH038A101CER
- NDH038B3 tons · 45 partsNDH038B111NSL
- NDH038G3 tons · 46 partsNDH038G111CER0BA
- NDH049A4 tons · 47 partsNDH049A111NSR
- NDH049G4 tons · 47 partsNDH049G111CSR0AN
- NDH049H4 tons · 45 partsNDH049H111CEL0DA
- NDH064G5 tons · 46 partsNDH064G111CER0AN
- NDH072A6 tons · 43 partsNDH072A101NEL
- NDV026B2 tons · 40 partsNDV026B101CTR
- NDV026G2 tons · 39 partsNDV026G111CTL0AN
- NDV038A3 tons · 44 partsNDV038A101CTR, NDV038A111CTL, NDV038A111NTL
- NDV038B3 tons · 43 partsNDV038B111NTR
- NDV038G3 tons · 43 partsNDV038G111CTL0BA, NDV038G111CTL0BN
- NDV038H3 tons · 49 partsNDV038H111NTL0CA, NDV038H114CTR0AA
- NDV049A4 tons · 44 partsNDV049A101NTL, NDV049A111CTL, NDV049A111CTR, NDV049A111NTL, NDV049A141CTR
- NDV049G4 tons · 45 partsNDV049G111CTL0AA, NDV049G111CTL0DA, NDV049G111CTR0BA, NDV049G111NTL0AA, NDV049G111NTR0AN
- NDV049H4 tons · 44 partsNDV049H101CTL0BN, NDV049H101NTL0DA, NDV049H111CTR0DA
- NDV049J4 tons · 38 partsNDV049J101CTL0DN
- NDV064A5 tons · 43 partsNDV064A101CTL, NDV064A111CTL, NDV064A111CTR, NDV064A111NTL, NDV064A111NTR, NDV064A141CTL
- NDV064G5 tons · 43 partsNDV064G111CTL0DA, NDV064G111CTR0BN, NDV064G111CTR0DA, NDV064G111NTL0BA
- NDV064K5 tons · 40 partsNDV064K111CTR0DNW
- NDV072A6 tons · 43 partsNDV072A111CTR, NDV072A111NRR, NDV072A111NTR, NDV072A141CTR
- NDV072G6 tons · 42 partsNDV072G111CTR0BA, NDV072G111CTR0CA
- NDV072H6 tons · 41 partsNDV072H111NTR0DA
- NDZ026H2 tons · 32 partsNDZ026H100NNN0AA
- NDZ038J3 tons · 32 partsNDZ038J100CNN0AA
- NDZ049G4 tons · 38 partsNDZ049G110CNN0AA
- NDZ064A5 tons · 37 partsNDZ064A11AC
- NDZ064G5 tons · 37 partsNDZ064G110CNN0AA
WaterFurnace 7 Series
- NVH036A3 tons · 46 partsNVH036A101CEL0KN
- NVH048A4 tons · 50 partsNVH048A111CER0KN
- NVH048D4 tons · 51 partsNVH048D111NER0KN
- NVV036A3 tons · 47 partsNVV036A101NTL0JN, NVV036A102CTL0KN
- NVV036C3 tons · 45 partsNVV036C101CTL0JN
- NVV048A4 tons · 48 partsNVV048A101CTL0KN, NVV048A101CTR0KN, NVV048A111CTL0KN
- NVV060A5 tons · 45 partsNVV060A101CBR0KN, NVV060A101CTL0KN, NVV060A101CTR0KN
- NVV060C5 tons · 48 partsNVV060C111CTL0KN
- NVV060D5 tons · 47 partsNVV060D111CTR0KN
Not listed? We only show model numbers we have built a confirmed parts list for. Send us your model and serial number and we’ll look it up.
How to read a WaterFurnace Envision NXW Chiller model number
Example: NXW360R3AEBNNSSH.
| Position | Example | Meaning | Codes |
|---|---|---|---|
| 1-3 | NXW | Product line | NXW = Envision water-to-water reversible chiller |
| 4-6 | 360 | Capacity (MBtu/h) | 096, 108, 120, 140, 180, 210, 240, 360, 540 (8 to 50 tons; 240 = 20 tons, 360 = 30 tons) |
| 7 | R | Operation | R = reversible |
| 8 | 3 | Voltage | 3 = 208-230/60/3, 4 = 460/60/3, 5 = 575/60/3, 8 = 380/60/3 |
| 9 | A | Phase protection / disconnect | P = phase guard in the 2010 manual; later vintages add other letters |
| 10 | E | Chassis | E = enclosed, F = open frame |
| 11 | B | Controls | Option letter depends on vintage |
| 12-13 | NN | Future use | N |
| 14-15 | SS | Non-standard options | SS = standard |
| 16 | H | Vintage | Design revision letter |
Source: WaterFurnace Envision NXW installation manual (NXW 8 to 50 tons, 2010 nomenclature). Letters that changed in later vintages are not decoded here.
WaterFurnace manuals
- WaterFurnace commercial naming conventionShows the Envision2 NXW chiller among the previous names now grouped under TruClimate 100.
WaterFurnace Envision NXW Chiller tech guides
- WaterFurnace Aurora Base Control Fault Codes and Related PartsOn the WaterFurnace Aurora Base Control, the red LED1 flash count is the fault code: 1 input fault, 2 high pressure, 3 low pressure, 4 freeze detection 2, 5 freeze det...
- WaterFurnace High or Low Pressure Lockout (Codes 2 and 3): Causes and FixesCode 2 is a high pressure lockout and code 3 is low pressure. Three faults in a row lock the unit out.
- How to Reset a WaterFurnace Lockout (and Why Manuals Disagree)Reset a WaterFurnace Aurora Base Control lockout by removing thermostat inputs Y1, Y2 and W for 3 seconds or more, cycling power, or using the emergency shutdown input.
WaterFurnace Envision NXW Chiller parts questions
Where do I find my NXW model number?
On the chiller’s nameplate. The capacity is in positions 4 to 6: 240 is a 20-ton unit and 360 is a 30-ton unit.
My part isn’t on the list. Can you still get it?
Usually, yes. A chiller has hundreds of components and our lists leave out things like screws, panels and niche items. Please contact us with the full model and serial number.