Skip to content

Carrier Furnace Code 32, Inducer Won't Start: Checks and Which 326628 Inducer Kit to Order

On a Carrier 58CVA or 58CVX two-stage furnace, status code 32 means "LOW-HEAT PRESSURE SWITCH DID NOT CLOSE OR REOPENED". Carrier's troubleshooting guide for these furnaces lists a "Defective inducer motor" as one cause, and if the inducer gets line voltage but does not turn, the guide says to replace the inducer motor or inducer motor assembly. If the label on your old assembly reads 326628-762, the part is Carrier 326628-762 Blower Motor 115V — Replacement, our verified replacement for Carrier 326628-762. Carrier's kit form, Form 58CT-2SI, explains which 326628 kit goes with which furnace input.

What does status code 32 mean on a Carrier 58CVA / 58CVX?

The furnace control flashes a two-digit status code. The code 32 entry in Carrier's troubleshooting guide for the 58CVA / 58CVX (variable-speed, two-stage, 4-way multipoise) lists these items to check for:

  • "Proper vent sizing."
  • "Defective inducer motor."
  • "Low inducer voltage (115 VAC)."
  • "Defective pressure switch."
  • "Low inlet gas pressure (if LGPS used)."
  • "Excessive wind."
  • "Inadequate combustion air supply."
  • "Restricted vent."
  • "Disconnected or obstructed pressure tubing."

Code 31 is the high-heat version. The guide's summary for code 31 says the "Control relay may be defective or gas valve is mis-wired" and refers you back to code 32.

Item Value in the 58CVA / 58CVX guide
Low-heat pressure switch (LPS) timing Checked 30 seconds after a call for heat; if it fails to close within 5 minutes, the control shuts the unit down and waits 15 minutes before restarting the heating cycle
LPS setting Make 0.33 in. w.c., break 0.18 ±0.05 in. w.c.
High-heat pressure switch (HPS) setting Make 0.42 in. w.c., break 0.27 ±0.05 in. w.c. (high altitude: make 0.36, break 0.21 ±0.05)
Recommended line voltage "between 104 and 127 VAC"

How do I check if the inducer motor is the cause?

  1. Read the code before you open the blower door. Write down code 32 (or 31) from the control's LED.
  2. Check vent, combustion air and pressure tubing first. These are on Carrier's code 32 list next to the inducer. A disconnected or blocked tube to the pressure switch gives the same code with a good inducer.
  3. Jumper R and W/W1 and watch the inducer. The guide asks: "Did the inducer motor turn on at all after jumpering R and W/W1?" If it ran, move on to the pressure switch checks. If it did not, go to the next step.
  4. Check voltage at the inducer plug. The guide asks: "Is 115-vac across PL11-1 and PL11-3?" If yes: "Replace inducer motor or inducer motor assembly."
  5. If there is no voltage at PL11, check the control output. Next question: "Is 115-vac across PL2-2 and NEUTRAL-L2?" If yes, the guide says you have "an open wire or bad terminal on the BLACK or WHITE wire from the variable speed furnace control to the inducer motor." If no, it says to replace the variable speed furnace control.
  6. Check line voltage. Low inducer voltage is on the code 32 list. The recommended range is 104 to 127 VAC; if line voltage is low, the guide says to contact the power utility.
  7. Run the component test after the repair. With no thermostat inputs and all time delays expired, turn on setup switch SW1-6. The guide says the control "turns the inducer motor ON at high-heat speed," turns the hot surface igniter on for 15 seconds, runs the blower at mid-range airflow for 15 seconds, then "switches the inducer to low-heat speed for 10 seconds, then OFF."

Which 326628 inducer kit fits my furnace?

Carrier Form 58CT-2SI covers the "Replacement Inducer Motor Assembly Kit" numbers 326628-760 through 326628-765. It says the instruction "covers the inducer motor assembly installation on non-condensing, 33.3-inch high," mid-efficiency hot surface ignition units. Carrier picks the kit by furnace input and by furnace type. For two-stage and variable-speed furnaces, Table 2 of the form reads:

Furnace input (BTUH) Kit in Form 58CT-2SI, Table 2 (two-stage / variable speed)
45,000 326628-760
70,000 326628-761
90,000 326628-762
110,000 326628-763
135,000 326628-764

Table 2 also lists kit 326628-765 for the largest input; confirm its row on the form. Single-stage furnaces use a different table (Table 1) in the same form, so use Table 1 for a single-stage furnace. The form also warns: "Using the incorrect inducer motor assembly could result in no pressure switch operation, poor ignition, poor combustion".

About the listing name: our listings for these numbers are titled "Blower Motor 115V". It is the same part number that Carrier's form calls an inducer motor assembly kit; it is not the furnace's main circulating blower. Order by the 326628 number on your old assembly or by the form's table, not by the listing name.

Parts that fix it

Component Role Link
Inducer motor assembly, 326628-762 Primary fix when the inducer has 115 VAC at PL11 and does not run. Table 2 kit for 90,000 BTUH two-stage / variable-speed units. Replaces Carrier 326628-762. Carrier 326628-762 Blower Motor 115V — Replacement
Inducer motor assembly, 326628-761 Table 2 kit for 70,000 BTUH units. Replaces Carrier 326628-761. Carrier 326628-761 Blower Motor 115V 60HZ — Replacement
Inducer motor assembly, 326628-763 Table 2 kit for 110,000 BTUH units. The listing also replaces Carrier 326628-703, 326628-713, 347822-763, 349336-763 and HC21ZE127. Carrier 326628-763 Blower Motor 115V — Replacement

More parts are in our Carrier Replacement Parts collection.

Which units this applies to

  • Code 32 / 31 checks, pressure switch values and the component test: Carrier 58CVA and 58CVX (Low NOx) variable-speed, two-stage furnaces, covered by Carrier's two-stage furnace troubleshooting guide (file TG-GFC80-02).
  • Kit selection: non-condensing, 33.3-inch high, mid-efficiency hot surface ignition furnaces, per Carrier Form 58CT-2SI.
  • Parts: any assembly whose label reads 326628-761, 326628-762 or 326628-763, or a number the 326628-763 listing also replaces.

Scope: The troubleshooting guide does not list inducer part numbers, and Form 58CT-2SI does not name furnace models. This article does not claim that a given 58CVA or 58CVX uses a given kit. Confirm the kit from the number on your old inducer assembly, or from your furnace's input, type (single-stage or two-stage) and cabinet height against Form 58CT-2SI.

Before you order

Have the furnace model and serial number from the rating plate, the input (BTUH) and the number on the old inducer assembly. Form 58CT-2SI lists a single-stage adapter harness, a mounting gasket and screws as Carrier kit contents; ask us what ships with the replacement before you start. If anything does not match, contact us or email help@totalhvacparts.com with the model, serial and old part number and we will check it before you order.

Frequently Asked Questions

What does code 32 mean on a Carrier two-stage furnace?

On the 58CVA / 58CVX, code 32 is "LOW-HEAT PRESSURE SWITCH DID NOT CLOSE OR REOPENED." Carrier's list of causes includes a defective inducer motor, low inducer voltage, a defective pressure switch, vent and combustion-air problems and disconnected or obstructed pressure tubing.

When should I replace the inducer motor?

Carrier's guide says to replace the inducer motor or inducer motor assembly when it did not run after jumpering R and W/W1 and 115 VAC is present across PL11-1 and PL11-3.

Which 326628 kit is for a 90,000 BTUH two-stage furnace?

Table 2 of Carrier Form 58CT-2SI lists 326628-762 for 90,000 BTUH two-stage and variable-speed furnaces. Single-stage furnaces use Table 1.

Can I seal the inducer with RTV instead of the gasket?

No. Form 58CT-2SI says: "Do not use RTV in place of inducer gasket." It warns RTV may flow onto the inducer wheel and put it out of balance.

Sources

Safety: Only qualified service personnel should do this work. Turn off gas and electrical supplies and lock out / tag out power before opening the furnace. Form 58CT-2SI warns that the vent elbow, vent connector or inducer motor may be hot.

← Greenheck Fire/Smoke Damper Stuck Closed ...Greenheck Kitchen Controls 'Temp Sensor E... →